Get a Quote

400G

400G QSFP112 DR4

Energy-efficient 400G QSFP112 DR4 optical transceiver for high-density data center interconnects.

400G QSFP112 DR4

Communication Products

Product Overview

In terms of design, the 400G QSFP112 DR4 takes full account of energy utilization efficiency. By applying advanced chip technologies and optimized circuit designs, it effectively reduces its own power consumption level. The relatively low power consumption not only helps to cut down the energy consumption in places like data centers and thus reduce the operating costs, but also alleviates the heat dissipation pressure caused by equipment heating, further enhancing the overall stability and reliability of the equipment and prolonging its service life. This is in line with the current trend of green and energy-saving development.

Performance Specifications – Optical

Transmitter Optical Specifications

ParameterSymbolMinTyp.MaxUnit
Transmitter
Centre Wavelengthλ1311nm
SMSR30dB
Average launch power, each lanePout–2.94dBm
Outer OMA, each laneNote5OMAouter-0.84.2dBm
Launch Power in OMAouter minus TDECQ, each laneTOMA-2.2dB
Transmitter and dispersion eye closure for PAM4TDECQ3.4dB
TDECQ – 10log10(Ceq)3.4dB
Optical Return Loss ToleranceTOL21.4dB
Average POUT (Laser Turn off)Poff-15dBm
Extinction Ratio,each laneER3.5dB
Transmitter transition time17ps
RIN17.1OMARIN-136dB/Hz
Transmitter ReflectanceTr-26dB

Receiver Optical Specifications

ParameterSymbolMinTyp.MaxUnit
Receiver
Centre Wavelengthλ1311nm
Damage threshold, each lanePd5dBm
Average receive power, each lanePa-5.94dBm
Receive power (OMAouter), each laneRXoma4.2dBm
Receiver Reflectance-26dBm
Receiver Sensitivity (OMAouter), each lane Note 6SOMA-4.4dBm
Stressed eye closure for PAM4 (SECQ) Note 73.4dB
SECQ – 10log10(Ceq), lane under test3.4
OMAouter of each aggressor lane4.2dBm

Technical Notes

  • Even when TDECQ is below 1.4 dB, the minimum OMAouter must exceed the specified value.
  • Receiver sensitivity (OMAouter), each lane maximum, is informative and is defined for a transmitter with SECQ up to 3.4 dB.
  • Measured with a conformance test signal at TP3 for BER = 2.4×10−4.

Need a customized telecom solution?

Send your target application, quantity and technical requirements. Our team will prepare a suitable product plan.