Get a Quote

Mechanical Optical Switches

Dual 2×2 Bypass Mechanical Optical Switch

Dual 2x2 Bypass Mechanical Optical Switch The Dual 2x2 Bypass Mechanical Fiber Optical switch connects optical channels by directing or blocking an incoming optical signal into the output fiber. This is achieved using a patent pending opto-mechanical configura

Dual 2×2 Bypass Mechanical Optical Switch

Communication Products

Product Overview

Dual 2×2 Bypass Mechanical Optical Switch

The Dual 2×2 Bypass Mechanical Fiber Optical switch connects optical channels by directing or blocking an incoming optical signal into the output fiber. This is achieved using a patent pending opto-mechanical configuration and activated via an electrical control signal. A latching version preserves the selected optical path after the drive signal has been removed, while the non-latching versions default to either the open or closed state when power is removed. TheMechanical Fiber Optical Switchhas integrated electrical position sensors. The new material based advanced design significantly reduces moving part position sensitivity, offering unprecedented high stability as well as unmatched low cost

Dual 2x2 Bypass Mechanical Optical Switch

Specifications

Operating Wavelength

1260~1620nm(SM)

850nm(MM)

Insertion Loss

≤1.0dB

Wavelength Dependent Loss

≤0.25dB

Polarization Dependent Loss

≤0.05dB

Temperature Dependent Loss

≤0.20dB

Return Loss

SM≥50dB

MM≥30dB

Cross Talk

SM≥55dB

MM≥35dB

Switch Time

≤8ms

Repeatability

≤±0.02dB

Durability

≥107times

Operating Voltage

3 or 5V

Switch Type

Non-Latching/Latching

Operating Temperature

-20~+70℃

Storage Temperature

-40~+85℃

Optical Power

≤500mW

Dimension

27.0L×12.0W×8.2H mm

Pin Configurations

Type

Optical Route

Electric Drive

State Sensor

D2×2B

Pin 1

Pin5

Pin6

Pin10

Pin 2-3

Pin3-4

Pin7-8

Pin 8-9

Latching

P1-P1’、P2-P2’

P3-P3’、P4-P4’

V+

GND

Open

Close

Close

Open

P1-P3’、P2-P4’

GND

V+

Close

Open

Open

Close

Non-latching

P1-P1’、P2-P2’

P3-P3’、P4-P4’

V+

GND

Open

Close

Close

Open

P1-P3’、P2-P4’

Close

Open

Open

Close

Mechanical Dimensions (Unit:mm)

Dual 2x2 Bypass Mechanical Optical Switch


Optical Route

Dual 2x2 Bypass Mechanical Optical Switch

Ordering Information

RD-FSW

-D2X2B-

-Wavelength-

-Switch Type-

-Voltage-

-Fiber Type-

-Package-

-Fiberlength-

-Connector-

1060=1

C+L=2

1310=3

1410=4

1550=5

650=6

780=7

1260-1610=A

1310/1550=9

850=8

Special=0

Latching=1

Non-latching=2

MINI Latching=3

MINI Non-latching=4

Special=0

3V=3

5V=5

Special=0

SM28=1

50/125=5

62.5/125=6

Special=0

Bare fiber=1

900um tube=3

Special=0

0.25m=1

0.5m=2

1.0m=3

Special=0

None=1

FC/PC=2

FC/APC=3

SC/PC=4

SC/APC=5

ST/PC=6

LC/PC=7

Duplex LC=8

Special=0

Product details are organized for Stellar Fusion network accessory applications.

Need a customized telecom solution?

Send your target application, quantity and technical requirements. Our team will prepare a suitable product plan.